SET FOR SEROLOGICAL DIAGNOSIS OF BOVINE ADENOVIRUS INFECTION IN INDIRECT HEMAGGLUTINATION REACTION (IHA)
Main characteristics of the kit
- Trade Name
- SET FOR SEROLOGICAL DIAGNOSIS OF BOVINE ADENOVIRUS INFECTION IN INDIRECT HEMAGGLUTINATION REACTION (IHA)
- Contents of the kit
-
- Specific erythrocyte adenovirus antigen
- Control erythrocyte antigen
- Specific hyperimmune serum
- Control serum
- Diluent serum
- Indications for use
- Detection of antibodies to bovine adenovirus infection in indirect hemagglutination reaction
Description
The active ingredient in the diagnosticum is an adenovirus antigen sensitized in a 3% suspension of red blood cells.
Release form
The diagnostic kit is available in liquid form.
Composition
The diagnostic kit includes the following components:
- Specific erythrocyte adenovirus antigen – 1 vial of 13.0 cm³
- Control erythrocyte antigen – 1 vial of 13.0 cm³
- Specific hyperimmune serum – 1 vial of 1.0 cm³
- Control serum – 1 vial of 1.0 cm³
- Diluent serum – 1 vial of 2.0 cm³
Indications
The kit is designed to detect antibodies to adenovirus infection in cattle using the indirect hemagglutination reaction.
Method of application
Blood serum samples from sick and recovered animals are used as the samples to be analyzed, at the beginning of the disease and 3-4 weeks later.
At least 15-20 serum samples are sent for testing. The sera are stored under conditions that prevent bacterial growth at a temperature of 2 to 8°C for no more than 15 days.
For longer storage (up to 2 months), boric acid can be added as a preservative (2-3 crystals per 1.0 cm³ of serum). After dissolving, diagnostic hyperimmune serum can be stored at 2-8°C in a test tube with a rubber stopper for up to 10 days. Serum can also be stored at -20°C for up to a month, and it should be thawed at room temperature before testing.
Paired sera should be examined simultaneously (regardless of the results of the first examination), and the first serum should be stored frozen before examination.
Serum samples with pronounced hemolysis, bacterial growth, or those that have been stored for a long time without freezing or have been repeatedly frozen are not allowed.
All samples to be examined must be identified (labeled).
Marking of components
Labels are attached to the vials containing the following information: the name of the manufacturer, its address and trademark, the name of the component, the volume in the vial, the batch number, the date of manufacture, the working dilution of the component, the expiration date, and the designation of the Standard.
According to the package, the bottles are packed in cardboard boxes according to GOST 33781 or in plastic (polystyrene) containers with dividing partitions that ensure their stability and integrity.
Each box contains an instruction manual for using the diagnostic kit.
Each package with a set of vials is labeled with the following information: the name of the manufacturer, its address and trademark, telephone number, name of the components, number of vials in the box, serial number, date of manufacture (month, year), expiration date (month, year), number of tests, storage conditions, and designation of the Standard.
Preparation of components and solutions for assay
The following preparatory work is required for the IHA:
- prepare a 0.15 M solution with a pH of 7.2-7.4;
- prepare the diluent;
- get the test serum.
To prepare a 0.15 M solution with a pH of 7.2-7.4, add 20.4 g of chemically pure anhydrous monosodium phosphate to a 1.0-liter measuring flask, dilute with distilled water to the mark, and bring the volume to 1.0 liter (solution A). In another 1.0-liter measuring flask, add 26.7 g of chemically pure sodium dihydrogen phosphate dihydrate, dissolve in a small amount of water, and bring to a volume of 1.0 liter (solution B). Solutions A and B can be stored at a temperature of 2-8°C for a month. To prepare the buffer, add 76.0 cm³ of solution B to 24.0 cm³ of solution A and add 0.85 g of chemically pure sodium chloride. The pH of the buffer is checked using a pH meter, and if necessary, it is adjusted to pH 7.2-7.4 using solutions A or B.
To prepare the diluent, 1.0 cm³ of normal rabbit blood serum is added to 100 cm³ of buffer. To do this, the serum bottle is shaken and the contents of the bottle are transferred to the buffer. The diluent is then heated at 65-66°C for 40 minutes, allowed to cool at room temperature, and then 0.3 cm³ of formalin is added and filtered through a paper filter. The diluent is stored at room temperature for one month. When a cloud appears at the bottom of the diluent container, it is filtered again. The cloudy diluent is not used.
For diagnostic purposes, the serum is diluted 1:2 with distilled water, transferred to a sterile test tube, and heated for 30 minutes at a temperature of 55-57°C.
The vial with erythrocyte antigen is thoroughly shaken until the contents are completely homogenized, and 1.0 cm³ is sterilely removed and transferred to a vial with 2.0 cm³ of diluent (0.15M phosphate-buffered saline with a pH of 7.2-7.4, with the addition of 1.0% normal rabbit serum by volume of the buffer).
Performing Analysis
The indirect hemagglutination reaction is performed using a microplate method with U-shaped wells for single-use immunological reactions.
0.05 cm³ of diluent is added to each well of the microplate. 0.05 cm³ of the test serum is added to the first wells of each row. Two rows of wells are required for each test serum. The test sera are then diluted 2-fold, from 1:2 to 1:4096. Then, 0.025 cm³ of a 1.0% suspension of a specific adenovirus erythrocyte antigen is added to the first row of wells, and 0.025 cm³ of a 1.0% suspension of a control erythrocyte antigen is added to the second row. The panel is shaken, covered with a special lid, and left at room temperature for 2-3 hours.
The reaction is accompanied by the following controls:
a) control for the absence of spontaneous agglutination of specific and control erythrocyte antigens.
0.05 cm³ of diluent is added to two rows of wells, then 0.025 cm³ of a 1.0% suspension of adenovirus specific erythrocyte antigen is added to the first row of wells, and 0.025 cm³ of a 1.0% suspension of control erythrocyte antigen is added to the second row;
b) control for the absence of agglutination of the specific adenovirus erythrocyte antigen and the control erythrocyte antigen with the control serum of cattle.
0.05 cm³ of diluent is added to two rows of microplate wells, and 0.05 cm³ of control cattle serum is added to the first wells and titrated. Then, 0.025 cm³ of a 1.0% suspension of adenovirus specific erythrocyte antigen is added to the first row, and 0.025 cm³ of a 1.0% suspension of control erythrocyte antigen is added to the second row;
c) control for the activity of a specific erythrocyte antigen of adenovirus with a specific serum of cattle. In a row of micropanel wells, 0.05 cm³ of diluent is added, in the first well, 0.05 cm³ of specific serum is added and titrated as the test sera, then 0.025 cm³ of 1.0% suspension of a specific erythrocyte antigen of adenovirus infection is added;
d) control of specific serum for the presence of antibodies to the control erythrocyte antigen. 0.05 cm³ of specific serum for the adenovirus antigen is added to a series of microplate wells and titrated, followed by 0.025 ml of a 1.0% suspension of the control erythrocyte antigen.
Registration of results
The reaction results are recorded after 2-3 hours at room temperature, and the presence or absence of erythrocyte agglutination is determined.
The reaction is considered positive (evaluated for " + "if agglutinated erythrocytes evenly line the bottom of the well, forming the shape of an inverted"umbrella".
The reaction is considered negative (rated as "-" when the erythrocytes settle at the bottom of the well in the form of a disk or a compact ring with a clear, even edge.
Note. In the first wells of the plate, there may be a "phenomenon" of sliding of agglutinated red blood cells with the formation of a ring with an uneven edge along the edge of the well (the "umbrella folding" effect).
The highest serum dilution that produces clear agglutination, such as uniform "umbrella" agglutination of red blood cells throughout the entire well, is used to determine the antibody titer in the RHA test.
The reaction is recorded only if the results obtained in the controls are clear.
Response controls:
- in the control wells for spontaneous agglutination, the red blood cells should settle as a dot or a dense ring
- the titer of the control serum with adenovirus-specific erythrocyte antigen and the control antigen should not exceed 1:8
- the titer of antibodies in a specific serum with a specific adenovirus erythrocyte antigen should be at least 1:128, and with a control erythrocyte antigen, it should be at least 1:8
The results of the IHA with the test sera are evaluated by the titer of antibodies. A positive result is considered to be sera that give with a specific erythrocyte antigen adenovirus infection titer 1:16 and higher.
If the test serum contains antibodies with a control erythrocyte antigen in titers greater than 1:8, the serum is considered positive if it contains antibodies with a specific erythrocyte antigen of adenovirus in titers that are 4 times or more higher than the control (for example, if the control is 1:32, the test serum should have a titer of at least 1:512).
Diagnosis of acute adenovirus infection and differentiation of vaccine antibodies. An increase in titers in paired sera of 4 times or more indicates the presence of infection.
Procedure for filing a complaint
In the event that the diagnostic set does not meet the requirements specified in this manual, or if it is ineffective, the use of this series of the product should be discontinued. The manufacturer is responsible for monitoring the diagnostic set that is subject to complaints.
Special Precautions
When conducting research, it is necessary to:
- work in boxed rooms for microbiological research using personal protective equipment (protective clothing and disposable rubber gloves);
- avoid contact with skin and mucous membranes, and immediately rinse with plenty of water if contact occurs;
- do not pipette with your mouth;
- in the event of spills of samples and working solutions on working surfaces, it is necessary to carry out disinfection treatment using disinfectants whose effectiveness has been confirmed in relation to the pathogen used in the work;
- tools and equipment (before and after use) should be treated with 70% ethyl alcohol or disinfectants that have been proven to be effective against the pathogen in question;
- the remaining test serum samples and polystyrene plates are disinfected by immersion in a 3% chloramine solution for 5 hours or by autoclaving at 0.5 atm for 30 minutes;
- the remaining diagnosticum and acroleolized sheep red blood cells do not require special disposal conditions and can be poured into the sewer.
Manufacturer
Agrovet LLC, 109472, Moscow, Tashkentskaya Street, 34, Building 5